BioPAT® Trace Calibration Solution | 2g/L EtOH

BioPAT® Trace Calibration Solutions are specifically developed for use with BioPAT® Trace and BioPAT® Multi‑Trace systems, enabling precise in‑process monitoring of critical parameters such as glucose, lactate, methanol, and ethanol.

They are employed for two‑point calibration of the biosensor, with the appropriate calibration solutions selected based on the required measurement range and the specific needs of the process.

Calibration is carried out prior to measurement and then automatically repeated at predefined intervals during operation. As ready‑to‑use solutions, they are ideally suited for the monitoring and control of key process variables in compatible Sartorius systems.

Calibration solution type with measurement range
Calibration Standards
Item No.: 
BPT0057
*Custom/bulk order quotes are provided within 72 hours of request.
BioPAT® Trace Calibration Solution | 2g/L EtOH
BioPAT® Trace Calibration Solution | 2g/L EtOH

BioPAT® Trace Calibration Solutions are specifically developed for use with BioPAT® Trace and BioPAT® Multi‑Trace systems, enabling precise in‑process monitoring of critical parameters such as glucose, lactate, methanol, and ethanol.

They are employed for two‑point calibration of the biosensor, with the appropriate calibration solutions selected based on the required measurement range and the specific needs of the process.

Calibration is carried out prior to measurement and then automatically repeated at predefined intervals during operation. As ready‑to‑use solutions, they are ideally suited for the monitoring and control of key process variables in compatible Sartorius systems.

Item No.:
BPT0057

Overview

Specifications

BioPAT® Trace and BioPAT® Multi‑Trace systems rely on two calibration solutions and a transport buffer to operate and to accurately quantify parameter concentrations in the sampled vessel. The liquids are connected to the designated ports of the tube set and are automatically circulated within the system loop.

Each calibration solution is supplied with a defined expiration date to ensure consistent measurement accuracy and long‑term analytical reliability. Test certificates are available for every calibration solution on request. Multiple combinations of calibration standards are offered to optimally cover typical concentration ranges.

The appropriate concentration range depends on the specific process conditions and cultivation objectives. For optimal measuring accuracy, process concentrations should generally lie between the values of the two calibration standards. It is also recommended to include a standard with a very low concentration to reliably determine values close to zero.

For control applications, the concentrations of the calibration standards should be selected in reasonable proximity to the regulation (set) point.

Applications

  • Application
    Process Analytical Technologies (PAT)
  • Usage
    Single-use

Calibration

  • Calibration Standards
    ethanol monitoring and control

Features

  • Device/Instrument Compatibility
    • Biostat® B
    • Biostat® B-DCU
    • Biostat® STR
    • Biobrain® Supervise

General Specifications

  • Calibration solution type with measurement range
    2g/L EtOH

Product Information

  • Brand
    BioPAT® Trace

Volume

  • Capacity
    0.5 Liter